Nlm2 Series Intelligent ABS Circuit Breaker
Basic Info
Model No.: NLM2 Series
Product Description
Model NO.: NLM2 Series Operation: Manual Type Installation: Fixed Poles Number: 3 Function: Conventional Circuit Breaker Arcing Distance (Mm): 7000 Specification: gb HS Code: 88 Breaking Capacity: High Voltage Circuit Breakers Arc-extinguishing Medium: Oil-immersed Type Structure: ACB Type: Circuit Breaker Certification: Standard: GB 14048.2-2008, IEC 60947-2:2006 Trademark: Ville Origin: Ningbo Scope of Application
NLM2 Series intelligent adjustable molded case circuit breaker is new developed breakers following with NLM1 series, which adopts international advanced design and manufacturing technology.
The breaker has features: compact structure, small size, high breaking capacity, short electric arcing and complete internal accessories.
And functions such as overload long-delay inverse time lag, short-circuit short-time delay fused time lag and short-circuit instantaneous operation. And parameter uses DIP switches setting, which is convenient and intuitive.
Users can setup by themselves and compose required protection performance according to release types. It is easy to implement selective protection, making breaker equipment environment more reasonable in Power Distribution network.
Standard:
Standard: GB 14048.2-2008, IEC 60947-2:2006
Main Specification And Technical Parameters
Contact us if you need more details on Nlm2 Series Intelligent Abs Circuit Breaker. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Circuit Breaker、Switch. If these products fail to match your need, please contact us and we would like to provide relevant information.
NLM2 Series intelligent adjustable molded case circuit breaker is new developed breakers following with NLM1 series, which adopts international advanced design and manufacturing technology.
The breaker has features: compact structure, small size, high breaking capacity, short electric arcing and complete internal accessories.
And functions such as overload long-delay inverse time lag, short-circuit short-time delay fused time lag and short-circuit instantaneous operation. And parameter uses DIP switches setting, which is convenient and intuitive.
Users can setup by themselves and compose required protection performance according to release types. It is easy to implement selective protection, making breaker equipment environment more reasonable in Power Distribution network.
Standard:
Standard: GB 14048.2-2008, IEC 60947-2:2006
Main Specification And Technical Parameters
Product Model | NLM2-100 | NLM2-250 | NLM2-630 | NLM2-1250 | |||||||||
Frame Size Rated Current Inm (A) | 100 | 250 | 630 | 1250 | |||||||||
N of poles | 3,4 | 3,4 | 3,4 | 3,4 | |||||||||
Rated Current In (A) | 40 | 63 | 100 | 100 | 160 | 250 | 400 | 630 | 800 | 1000 | 1250 | ||
Rated Current Adjustable Scope Ir (A) | 16-40 | 25-63 | 40-100 | 40-100 | 64-160 | 100-250 | 160-400 | 252-630 | 320-800 | 400-1000 | 500-1250 | ||
Rated Insulation Voltage Ui (V) | 800 | ||||||||||||
Rated Impulse Withstand Voltage Uimp (V) | 75 | ||||||||||||
Rated Operational Voltage Ue (V) | 400,600 | ||||||||||||
Level of Breaking Capaciy | L | M | H | L | M | H | L | M | H | M | H | ||
Limiting Short-circuit Breaking Capacity Icu (kA) | 400V | 20 | 70 | 100 | 25 | 70 | 150 | 45 | 70 | 150 | 50 | 70 | |
Operating Short-circuit Breaking Capacity Ics (kA) | 400V | 20 | 70 | 100 | 25 | 70 | 150 | 45 | 70 | 150 | 75% Ics | 50% Ics | |
Arcing Distance (mm) | 50 | 100 | |||||||||||
Usage Category | A | B | |||||||||||
Operation Performance (times) | No-Loading | 7000 | 4000 | 2500 | |||||||||
0.5h loading | 1000 | 1000 | 500 | ||||||||||
Overcurrent Release | TM,STR22GE,STR22ME | STR23SE,STR53UE,STR23ME,STR43ME | Micrologic5.0 | ||||||||||
3-poles unbalance protection N=In/2 N=In | Mainly focus on motor protection or specific requirement of the users | ||||||||||||
Overall Dimension (mm) | 3P | 160*105*111 | 255*140*168 | 327*210*205 | |||||||||
4P | 160*140*111 | 255*185*168 | 327*280*205 | ||||||||||
Weight | 3P | 2.0-2.2 | 6.2-8.1 | 14 | |||||||||
4P | 2.6-2.8 | 18 |
Contact us if you need more details on Nlm2 Series Intelligent Abs Circuit Breaker. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Circuit Breaker、Switch. If these products fail to match your need, please contact us and we would like to provide relevant information.
Product Categories : Low Voltage Electric Equipments > Earthing Switch
Other Products
Hot Products
Centrifugal Ventilation Fan with Good QualityGood Price for Vacuum Circuit Breaker of High Quality and Low VoltagePower SaverRectifier Transformer /Oil Immersed Power TransformerPassive Power Filter (Low Voltage)DC Power Distribution Board of Transformer SubstationThree Phase Resin Insulation Dry Type Power TransformerDistribution Transformer /Power Transformer/Power SubstationCable Distribution Box for Outdoor High VoltageAuto Transformer 330kv-500kv Power Transformer Furnace Transformer220kv Combination Power TransformerElectric Arc Furnace Transformer /Power Supply Transformer Power Distribution TransmissionPackaged Box Type Power Transmission SubstationHigh Voltage Vacuum Circuit Breaker for IndoorMetal Clad Switchgear of Medium / High VoltageMetal Clad Switchgear of High Voltage