Metal-Clad Two-Layer Draw-out Type Switchgear
Basic Info
Model No.: KSN1-12(KYN39-12)
Product Description
Model NO.: KSN1-12(KYN39-12)
Structure: Protection
Form: All- packaged Type
Size: 1 Uint
Shell Material: Stainless Steel
Brand: Schneider
Rated Frequency: 50Hz
Degree of Protection: IP4X
Trademark: ville
Specification: IEC
HS Code: 85
Type: Distribution Metering Box
Certification: ISO9001:2000, CCC
Operation Voltage: Low Voltage
Application Range: Power Plants
Shell Protection Grade: IP55
Phase: 3 Phase
Rated Voltage (Kv): 3, 6, 7, 2, 12
Main Busbar Rated Current: 630, 1250, 1600, 2000, 2500, 3150
Transport Package: Wooden Case or as Per Requirement
Origin: Ningbo China
General:
KSN1-12(KYN39-12) Metal-clad Two-layer Draw-out Type Switchgear is a kind of indoor complete set of electric apparatus with 3~10kV, three phases alternative current 50Hz single busbar and single busbar segment system. It is mainly used in power plants, industrial and mining enterprise for Power Distribution, and for power feeding and electric Power Supply in the secondary substation of power supply system. And in big-size HV motor starting fields, it could be used as controlling, protection and monitoring. This switchgear is two-layer structure matched with inner main switch, which could be VT2 Vacuum Circuit Breaker and ZN18-12 vacuum Circuit Breaker, or VD4 vacuum circuit breaker and VRC vacuum circuit breaker by ABB. It meets specification of GB3906-91, IEC298 standard and having 5-protective functions and it features:
* Compatible with circuit breaker switch cubicle and F-C switch cubicle.
* Specially designed switchgear in order to reduce occupied area of substation.
* Matched excellent vacuum circuit breaker and contactor, soithasmiddle mounted switchgear function.
* Adopting international fashioned combination structures, completely metal-clad, so it satisfies complete separated.
* Aluminum zinc coated steel plate enclosure is not necessary to do any surface treatment to meet requirements of anti-corrosion.
* Satisfying IEC298 and GB3906-91 standards, it is an ideal product, which could be instead of imported products.
Technical Data:
Rated Voltage (kV) | 3,6,7,2,12 | |
Rated 1min power frequency withstand voltage | 16 20 42 | |
Horizontal Lightening impulse withstand voltage | 40 60 75 | |
Rated Frequency | 50 | |
Main Busbar Rated Current | 630, 1250, 1600, 2000, 2500, 3150 | |
Rated peak withstand current (peak value) (kA) | 16 31.5 40 50 63 80 | 100 125 |
4s Rated short-time withstand current (r.m.s.) (kA/s) | 6.3 12.5 16 20 25 31.5 | 40 50 |
Degree of protection | IP4X | |
Gross Weight (including packing ) kg | 700 | 800 |
Net Weight (including packing ) kg | 600 | 700 |
Dimensions (Width×Depth×Height) mm | 800×2100×2400 | 1000×2100×2400 |
Packing dimensions (Width×Depth×Height) mm | 1300×2160×2600 | 1500×2160×2600 |
Contact us if you need more details on Switchgear. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Draw out Type Switchgear、3 Phase Switchgear. If these products fail to match your need, please contact us and we would like to provide relevant information.
Product Categories : HV Switchgear
Premium Related Products
Other Products
Hot Products
Centrifugal Ventilation Fan with Good QualityGood Price for Vacuum Circuit Breaker of High Quality and Low VoltagePower SaverRectifier Transformer /Oil Immersed Power TransformerPassive Power Filter (Low Voltage)DC Power Distribution Board of Transformer SubstationThree Phase Resin Insulation Dry Type Power TransformerDistribution Transformer /Power Transformer/Power SubstationCable Distribution Box for Outdoor High VoltageAuto Transformer 330kv-500kv Power Transformer Furnace Transformer220kv Combination Power TransformerElectric Arc Furnace Transformer /Power Supply Transformer Power Distribution TransmissionPackaged Box Type Power Transmission SubstationHigh Voltage Vacuum Circuit Breaker for IndoorMetal Clad Switchgear of Medium / High VoltageMetal Clad Switchgear of High Voltage