Voltage Transformer Potential Transformers 10kv 35kv 17.5kv 40.5kv 110kv 252kv

Basic Info

Model No.:  10-230kv

Product Description

Model NO.: 10-230kv Type: Voltage Transformer Operation Condition: Outdoor Winding Form: Single Layer & Tightly Wound Type Installation: Extension Type Voltage Transformation Principle: Electromagnetic Type Trademark: VILLE Origin: Ningbo China Application: Electronic, Instrument Phase: Single Usage: Measurement Insulating Medium: Insulating Paper Magnetic Circuit Structure: Combined Type Test: Type Test Report Specification: IEC HS Code: 8
Voltage Transformer Potential Transformers 10kv 35kv 17.5kv 40.5kv 110kv 252kv
Voltage Transformer Potential Transformers 10kv 35kv 17.5kv 40.5kv 110kv 252kv
Voltage Transformer Potential Transformers 10kv 35kv 17.5kv 40.5kv 110kv 252kv
1.10KV-40.5  voltage transformer:
epoxy resin cast vacuum structure, with phase A and C in series connection to two instrument transformers separately
. It is suitable for indoor power system of 10KV and below for voltage, current and energy measuring. It is of three phase "V" connection with two full-insulated single phase instrument transformers.
2.JDQXF Series SF6 Gas-insulated Voltage Transformer
JDQXF-110W2 / JDQXF-110W3 126kv
3.GIS Gas-insulated Voltage Transformer 
JDQXF-110ZH 126kv 145kv 
4.JDC6-110 and JDCF-110 type Inductive Voltage Transformers
   JDC6-110 126KV
  JD6-35 and JDX6-35 type Inductive Voltage Transformers
5.TYD110/220 type Capacitor Voltage Transformer  
   T YD 110/220

     LB7-220
  Highest Voltage for Equipment kV 252
  Rated frequency Hz 50/60
  Rated power-frequency withstand voltage (rms) kV 460
  Rated lightning impulse withstand voltage (full wave)(peak) kV 1050
  Rated lightning impulse withstand voltage (full wave)(peak) kV 1050
  Rated lightning impulse withstand voltage (chopped wave)(peak) kV 1208
  Flashover distance mm 2200
  Creepage distance mm 6300 W2) 7900 W3
  Rated secondary current A 1; 5
  Rated primary current (Maximum) A 2 600 2 800
  Accuracy classes (they can be combined if necessary) 0.2; 0.5; 0.2S; 0.5S; 5P; 10P
  Rated output VA 10~50
  Safety factor FS 5; 10
  Accuracy limit factor ALF 10; 15; 20; 30
  Short-time thermal current (Maximum) kA 50kA/3s (In series)
  Dynamic current (Maximum) kA 125
  Allowable mechanical load of transformer (Static) N 3000

Contact us if you need more details on Voltage Transformer. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Transformer、Distribution Transformer. If these products fail to match your need, please contact us and we would like to provide relevant information.